Non-Toxic Heat Transfer Fluid For Use In Closed Loop Lquid Phase
Temperature Control Systems
|
MultiTherm 503® is a high quality non-toxic heat transfer fluid for use in closed loop liquid phase temperature control systems for heating and cooling within the same loop from 10°F to 500°F. MultiTherm 503 has been successfully used in a variety of applications. In the Chemical Processing Industry, it has been used in temperature control systems for heating and cooling batch reactor systems. In the Plastics Industry, MultiTherm 503has been used for hot/cold cycling of molded products and to improve the versatility of laminating lines. MultiTherm 503provides you with a non-toxic, low pressure alternative to synthetic chemical based heat/cool fluids for your temperature control system. MultiTherm 503 meets the requirements for FDA regulations 21CFR178.3620(b) non-food articles in contact with food. REDUCES EQUIPMENT COSTS Use in Low Pressure Temperature Control SystemsFluids that have high vapor pressure can require complete system pressurization to prevent fluid boiling and pump cavitation. Pressure control systems on expansion tanks and pressure rated piping and equipment can add significantly to equipment costs. In addition, electrical classifications and system gasketing requirements are also affected by low flash point fluids. MultiTherm 503 can be used in standard low pressure fluid heating systems. It has low vapor pressure and high flashpoint (310°F). |
||||||||||||||||||||||||||||||||
Efficient Heat Transfer
MultiTherm 503 physical properties (viscosity, density, thermal conductivity and specific heat) result in higher fluid film coefficients than many other fluids. As a result, heat loads can be achieved with lower flow rates, smaller heat exchangers or lower approach temperatures.
LOWER EXPENSE
Reduced Maintenance CostsMultiTherm 503 can help reduce system maintenance costs. It has excellent metal coating properties and lubricity, which reduce wear on moving parts and protects surfaces from corrosion. Chemically inert, it will not attack gaskets and seals. And since MultiTherm 503 operates in low pressure equipment, there are no pressure control or purging systems to maintain.
Minimize Leak Testing
Fluids with high vapor pressure can require extensive leak testing prior to start-up to prevent fluid loss during operation. This can add significantly to total maintenance down time. With MultiTherm 503, system pressure is limited to pump circulating pressure so leak testing requirements are significantly reduced.