Micropump offers magnetic drives in standard and custom designs or the exclusive I-Drive electromagnetic drive. Micropump's drive configurations are designed to meet the specific performance requirements of OEM and industrial applications.
Drive Selection Chart
| DC - I-Drive® (Brushless) |
| I-Drive IEG |
J |
3 |
500-5500 |
15 oz-in (106 mNm) |
70W |
20-30 Volts |
N/a |
CE, LVD, EMC |
Wire leads |
0.96 |
2.1 |
| I-Drive IMS |
M |
3 |
500-6000 |
8 oz-in (56 mNm) |
40W |
20-30 Volts |
N/a |
CE, LVD, EMC |
Wire leads |
0.72 |
1.6 |
| DC - Brushless |
| 380 |
A |
3 |
500-4600 |
106/15 |
42/0.056 |
24V |
N/a |
UL/
CE |
Wire leads |
0.95 |
2.09 |
| 380 |
B |
3 |
500-4600 |
106/15 |
42/0.056 |
24V |
N/a |
UL/
CE |
Wire leads |
0.95 |
2.09 |
| DC - Brush Type Permanent Magnet |
| 305 |
A |
3 |
500-4000 |
190/27 |
90/0.12 |
12V |
N/a |
|
Wire leads |
1.14 |
2.51 |
| 306 |
A |
3 |
500-4000 |
212/30 |
112/0.16 |
24V |
N/a |
|
Wire leads |
1.14 |
2.51 |
| 331A |
C |
3 |
500-6000 |
25/3.5 |
11/0.15 |
12V |
N/a |
|
Spade terminals |
0.23 |
0.50 |
| 332A |
C |
3 |
500-6000 |
25/3.5 |
11/0.15 |
24V |
N/a |
|
Spade terminals |
0.23 |
0.50 |
| 335 |
C |
3 |
100-600 |
42/6 |
4/0.005 |
24V |
N/a |
|
Wire leads |
0.04 |
0.08 |
| 336 |
C |
3 |
500-8000 |
12/1.75 |
46/0.061 |
24V |
N/a |
|
Spade terminals |
0.27 |
0.60 |
| 337 |
C |
3 |
500-4000 |
25/3.5 |
8/0.011 |
24V |
N/a |
|
Wire leads |
0.32 |
0.70 |
| 346 |
B |
3 |
500-8800 |
25/3.5 |
143/
0.192 |
24V |
N/a |
|
Spade terminals |
0.36 |
0.80 |
| 348 |
A |
3 |
200-2000 |
148/21 |
42/0.056 |
30V |
N/a |
|
Wire leads |
1.00 |
2.20 |
| 361 |
C |
3 |
100-500 |
127/18 |
34/0.045 |
24V |
N/a |
|
Spade Terminals |
0.23 |
0.50 |
| AC - Variable Speed, Electronic Control |
| 810 |
6 |
3 |
500-4500 |
3.5/
495 |
550/0.73 |
220/
240V |
50/
60 |
CE |
Terminal box |
10.2 |
22.49 |
| AC - Shaded Pole |
| 604 |
A |
5 |
3450 |
127/18 |
38/0.05 |
115/
230V |
50/
60 |
UL/
CSA |
Wire leads |
2.72 |
5.98 |
| AC - Permanent Split Capacitor |
| 641 |
D |
5 |
3450 |
315/45 |
93/0.13 |
115/
230V |
50/
60 |
UL/
CSA |
Wire leads |
3.41 |
7.50 |
| AC - IEC, Single Phase |
| 671 |
A |
5 |
2680 |
450/63 |
75/0.10 |
220/
240V |
50/
60 |
CE |
Terminal box |
3.20 |
7.04 |
| 691 |
A |
5 |
1340 |
630/88 |
75/0.10 |
220/
240V |
50/
60 |
CE |
Terminal box |
3.20 |
7.04 |
| AC - IEC, Three Phase |
| 672 |
A |
3 |
2880 |
310/44 |
90/.12 |
230/400V
255/440V
|
50/
60 |
CE |
Terminal box |
5.70 |
12.54 |
| 692 |
A |
3 |
1380 |
650/92 |
90/.12 |
230/400V
255/440V |
50/
60 |
CE |
Terminal box |
5.70 |
12.54 |
| AC - Explosion Proof |
| 519 |
A |
4 |
3450 |
529/75 |
127/0.17 |
115/
230V |
50/
60 |
UL |
Wire leads |
9.03 |
19.87 |
| AC - Universal, Brush Type |
| 405A |
A |
2 |
9000 |
92/13 |
66/0.089 |
115V |
N/a |
|
Cord & plug |
4.20 |
9.24 |
| 415A |
A |
2 |
500-9000 |
92/13 |
66/0.089 |
115V |
N/a |
|
Cord & plug |
5.50 |
12.10 |
| Air Driven Vane Type |
| 951 |
B |
6 |
500-8000 |
355/50 |
250/0.33 |
5-100 psig |
N/a |
|
1/8 NPT ports |
1.04 |
2.29 |
| 955 |
A |
6 |
500-8000 |
355/50 |
250/0.33 |
5-100 psig |
N/a |
|
1/8 NPT ports |
1.04 |
2.29 |
| Programmable Drives |
| MCP-Z Process |
B |
|
60-6000 |
200/28 |
150/0.20 |
85/264 |
47/60 |
IP65 |
Cord & Plug |
6.9 |
16 |
| MCP-Z Standard |
B |
|
60-6000 |
150/21 |
150/0.20 |
115/
230V |
50/60 |
IP30 |
Cord & Plug |
6.4 |
14 |
| BVP-Z |
B |
|
60-6000 |
200/28 |
150/0.20 |
115/
230V |
50/60 |
IP30 |
Cord & Plug |
5.7 |
13 |
| Reglo-Z |
B |
|
50-6000 |
43/6 |
50/0.07 |
115/
230V |
50/60 |
IP30 |
Cord & Plug |
2.2 |
5 |
| Reglo-ZS |
B |
|
50-6000 |
43/6 |
50/0.07 |
115/
230V |
50/60 |
IP30 |
Cord & Plug |
1.6 |
4 |
|
Motor Enclosure Description Notes:
- I-Drive electromagnetic drive/Open drip proof, for dry, clean indoor environments, requires good ventilation EG/HG requires 0-5 V signal to change speed, HG has switch for 4-20ma and manual pot speed control. Note: weights listed for I-Drive motors (EG, HG, HGA) include pumphead
- Open drip proof, suitable for dry clean indoor environments, requires good ventilation
- IP55/Totally enclosed non-ventilated, suitable for humid, dusty atmospheres, requires good ventilation
- Totally enclosed non-ventilated. Explosion proof. Class 1/Groups C & D/Div. 1, NEMA 42 frame
- Totally enclosed fan cooled. Suitable for fairly clean damp environment
- Suitable for Explosion Proof and harsh environments, but not resistant to corrosive chemicals
- Ventilated
|