These high quality
electrodes will provide excellence performance at a price that
offers superior value. These electrodes may be used for General
Purpose applications. They are provided with the cables fixed
and hard-wired to the electrode, or with our popular cartridge
style connections (series S222).
The
General Purpose pH electrodes are available with spherical or flat
pH sensitive glass bulb designs. Choose either single or double
junction construction.
Fixed Cables with
Threaded Body
Sensorex is pleased
to announce the availability of our new low cost submersion and
in-line pH electrodes. These rugged pH electrodes are provided
with a molded Ryton body that is available with a 1/2" or
3/4" male NPT threads on each end. You may use these electrodes
in a standard threaded 1/2" or 3/4" pipe Tee, or submerse
them into a tank. Standar cable length is 10ft. Special
cable lengths are available at addtional cost. Specify
type of connector required at time of order.
|
| Product Features |
| |
One year shelf life,
guaranteed |
| |
Spherical bulb or
flat models |
| |
Sealed, gel-filled
no maintenance reference junctions |
| |
Compatible with most
pH meters, transmitters,
and controllers |
| |
In-Line or Submersion
mountings |
|
|
|
The Ryton body provides
excellent corrosion resistance to a wide range of chemicals.
Ryton provides excellent temperature resistance up to 100 degrees
C. Pressure rating is 0 to 100 psig (7 bar). Wetted
materials includepH glass, HDPE or pelon and silicone.
Ryton Nipple Bodies
Rated 0 - 100 psig (7 bar) up to 100° C
| S265C |
Single |
1/2" male NPT |
Spherical |
| S265CD |
Double |
1/2" male NPT |
Spherical |
| S267C |
Single |
3/4" male NPT |
Spherical |
| S267CD |
Double |
3/4" male NPT |
Spherical |
| S268CD |
Double |
1/2" male NPT |
Flat |
| S269CD |
Double |
3/4" male NPT |
Flat |
Quick
Disconnect Cartridge Style Electrodes
Our popular S222 series
electrodes are an easy, and very economical means of measuring
pH in-line in pipe Tee fittings, or submersed into tanks.
For in-line use, Sensorex
Electrode Glands are designed to be used with the S222C and the
S222CD Combination pH/Reference Electrode. Available in 1/2"
NPT (FC50P) and 3/4" NPT(FC75P) versions, they can be used at
temperatures up to 100 C (212 F) and pressures as high as 100
psig. The glands are reusable, and fit standard threaded pipe
Tees.
The gland uses an O-ring
seal and has a stainless steel gripper to assure electrode retention.
Gland materials contacting the sample are polypropylene and buna-N.
For the electrodes, materials contacting the sample include epoxy,
silicone rubber, nylon and glass.
With the use of 1/2 inch NPT threads of the S653 Cable Assembly, the quick disconnect S222 electrodes can also be used in Submersion Applications. This configuration reduces maintenance time when the electrode has to be removed for calibration or cleaning. In addition to the S222C or S222-ORP electrode, also order the S653 Cable Assembly and specify the required cable length and conenctor to mate with your pH transmitter or controller.
Rated 0 - 100 psig (7 bar) up to 100° C
Cartridge Style pH Electrodes
| S222C |
pH Electrode
Single Junction |
12 mm x 150 mm
1/2" x 6" |
| S222CD |
pH Electrode
Double Junction |
12 mm x 150 mm
1/2" x 6"
|
| FC50P |
Gland Fitting |
1/2" male NPT |
| FC75P |
Gland Fitting |
3/4" male NPT
|
| S653 |
Cap cable submersion |
1/2" male NPT |
| S648 |
cap cable in-line only |
N/A |
|