Using fans suitable for combustible environments, Noren Products offers air-to-air and air-to-water models for use in hazardous locations including Class I and II, Division 1 and 2 classifications. In both purge and non-purge applications where water is available for cooling, our air to water units are the ideal low cost, low maintenance solution. (Unit will not maintain NEMA 7 type enclosures.)
|
Typical applications
|
|
Class I
- Petroleum refineries
- Petrochemical companies
- Dry cleaning plants
- Applications near paint or plastic spraying
- Aircraft hangers, fuel servicing
- Utility gas plants
|
Class II
- Grain elevators, flour, feed mills
- Magnesium, aluminum powder
processing - Chemical, metallurgical processes
- Manufacturing of plastics, medicines, fireworks
- Starch or candy manufacturing
- Coal or carbon handling processing operations
|
- New XP fans now available for Class 1, Div 2 Group A,B,C and D are available for sale as a stand alone product or with the following heat exchangers in purged or non-purged applications:
- Purged and non-purged applications:
- AIR-to-AIR
CC500P, CC800P, CC1200P, CC1400P, CC2000P, CC600FP, CC900FP, CC1300FP, CC2500FP CC4000FP See Use Table
- AIR-to-WATER
CC3060P, CC3260P CC6360P See Use Table
- Purged applications only use:
- AIR-to-WATER CC2060P See Use Table
-
AIR-to-AIR CC851-XP, CC1251-XP See Use Table
- Safety: Important Notice
|
|
DIVISION 1
(Hazard is normally present)
|
DIVISION 2
(Hazard is not normally present)
|
|
Purge Type →
|
X purge
|
Y purge
|
Z purge
|
None (no purge)
|
|
Cabinet Cooler Type * →
|
XP
|
A/W
|
XP
+
IHL
|
A/W
+
IHL
|
XP
|
A/W
|
HL
|
XP
+
IHL
|
A/W
+
IHL
|
HL2
|
|
CLASS 1
|
|
GROUP A: Acetylene
|
No
|
2060P
3060P
3260P
6360P
|
No
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
No
|
2060P
3060P
3260P
6360P
|
CC500, 800, 1200, 1400, & 2000 P-HL.
CC600F, 900F, 1300F, 2500F, & 4000FP-HL
|
No
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
CC500, 800, 1200, 1400, & 2000 P-HL2.
CC600F, 900F, 1300F, 2500F, & 4000F P-HL2
|
|
GROUP B: Hydrogen, Manufactured Gas, etc.
|
No**
|
2060P
3060P
3260P
6360P
|
No**
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
No**
|
2060P
3060P
3260P
6360P
|
CC500, 800, 1200, 1400, & 2000 P-HL.
CC600F, 900F, 1300F, 2500F, & 4000FP-HL
|
No**
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
CC500, 800, 1200, 1400, & 2000 P-HL2.
CC600F, 900F, 1300F, 2500F, & 4000F P-HL2
|
|
GROUP C: Diethyl ether, ethylene, cyclopropane, etc.
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
851XP-IHL
1251XP-IHL
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
CC500, 800, 1200, 1400, & 2000 P-HL.
CC600F, 900F, 1300F, 2500F, & 4000FP-HL
|
851XP-IHL
1251XP-IHL
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
CC500, 800, 1200, 1400, & 2000 P-HL2.
CC600F, 900F, 1300F, 2500F, & 4000F P-HL2
|
|
GROUP D: Gasoline, hexane, butane, naphtha, propane, toluene, isoprene, alcohol, acetone, lacquer solvent, natural gas, etc.
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
851XP-IHL
1251XP-IHL
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
CC500, 800, 1200, 1400, & 2000 P-HL.
CC600F, 900F, 1300F, 2500F, & 4000FP-HL
|
851XP-IHL
1251XP-IHL
|
3060P-IHL, 3260P-IHL, 6360P-IHL
|
CC500, 800, 1200, 1400, & 2000 P-HL2.
CC600F, 900F, 1300F, 2500F, & 4000F P-HL2
|
|
CLASS 2
|
|
GROUP E: Flammable metal powders, etc.
|
(S)
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
No
|
No
|
(S)
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
No
|
No
|
No
|
No
|
|
GROUP F:
Carbon black, coal dust, coke dust, etc.
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
No
|
No
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
No
|
No
|
No
|
No
|
|
GROUP G:
Flour, starch, grain dust, etc.
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
No
|
No
|
851XP
1251XP
|
2060P
3060P
3260P
6360P
|
No
|
No
|
No
|
No
|
|
|
|
|
|
|
|
|
|
|
|
|
-
NOTES:
- All Cabinet Cooler models for Hazardous Location duty are pressure tested (P suffix) to assure a liquid tight and airtight seal.
- Type X purging changes the interior hazard class of the enclosure from Div. 1 to non-hazardous.
- Type Y purging changes the interior hazard class of the enclosure from Div. 1 to Div. 2.
- Type Z purging changes the interior hazard class of the enclosure from Div. 2 to non-hazardous.
-
*Cabinet Cooler Types:
- XP: Air to Air Unit with external Explosion Proof blower (internal fan is standard duty). Models: CC851XP, CC1251XP. Voltage: 115 or 230 VAC.
- A/W: Air to Water unit with no external electrical or moving parts (internal fan is standard duty). Models: CC2060P, CC3060P, CC3260P, CC6360P. Voltage: 115 or 230 VAC, 12, 24, or 48 VDC.
- IHL: Air to Water or XP Unit with Internal Hazardous Location fan(s): Air to Water models: CC3060P-IHL, CC3260P-IHL, and CC6360P-IHL. XP models include CC851XP-IHL, CC1251XP-IHL. Voltage: 115 VAC.
- HL: Air to Air Unit with external Hazardous Location Fan(s). Models: CC500P-HL, CC800P-HL, CC1200P-HL, CC1400P-HL, CC2000P-HL, CC600FP-HL, CC900FP-HL, CC1300FP-HL, CC2500FP-HL, CC4000FP-HL. Voltage: 115 VAC.
- HL2: Air to Air Unit with external
and internal
Hazardous Location Fan(s). Models: CC500P-HL2, CC800P-HL2, CC1200P-HL2, CC1400P-HL2, CC2000P-HL2, CC600FP-HL2, CC900FP-HL2, CC1300FP-HL2, CC2500FP-HL2, CC4000FP-HL2. Voltage: 115 VAC.
- No = Not usable
- ** = Explosion Proof Blowers for this environment may be available in the future.
- (S) = Special order
SAFETY: IMPORTANT NOTICE
USING NOREN “XP”, “HL”, “HL2”, “-IHL”, AND “AIR TO WATER” CABINET COOLERSTM IN HAZARDOUS LOCATIONS
- 1. Only use HL2 Cabinet CoolersTM without purged / pressurized systems if an internal Div 2 hazard condition is allowable. All fans are rated for Division 2 use.
- 2. Only use “Air to Water type IHL” Cabinet CoolersTM without purged / pressurized systems if an internal Div 2 hazard condition is allowable. The Internal Hazardous Location fan(s) are rated for Division 2 use.
- 3. Always use standard Noren “HL” Cabinet CoolersTM in conjunction with type Z purged / pressurized systems. The internal fan is not rated for hazardous use.
- 4. Noren “XP type IHL” and “Air to Water type IHL” Cabinet CoolersTM have Internal Hazardous Location fans rated for Division 2 use. This may permit the use of a Type Y purging system in Division 1 Locations if an internal Division 2 hazard condition is allowable.
- 5. Always use standard Noren “XP” or standard “Air to Water” Cabinet CoolerTM in conjunction with type X or type Z purged / pressurized systems.
- 6. Never use standard Noren “XP”, “HL”, or “Air to Water” Cabinet CoolerTM with type Y purged / pressurized systems. The internal fan is not rated for Div 2 use.
- 7. Only use Noren “XP” or “HL” Cabinet CoolersTM in locations for which the external XP (eXplosion Proof) or HL (Hazardous Location) motor is designed.
- 8. Read the hazard classification on nameplate of the motor(s) you receive to assure they are appropriate for your application.
- 9. Noren “Air to Water” Cabinet CoolerTM can be used in some hazardous locations where Noren XP or HL units cannot. Depending on which internal fan is used and your purging system, this may include Class 1, Div 1, Groups A & B (acetylene, hydrogen, manufactured gas). “Air to Water” Cabinet CoolesTM have no external electrical or moving parts.
- 10. Noren Cabinet CoolersTM will not maintain the explosion proof integrity of NEMA 7 type enclosures.
- 11. It is the customer’s responsibility to know what protection their purged / pressurized system provides. Install the Noren Cabinet CoolerTM correctly and safely in accordance with the National Electrical Code (N.E.C.
|