Digi-Sense,Dual,J,T,E,K,Thermocouple Thermometers,Oakton Instruments

Digi-Sense® Dual J-T-E-K Thermocouple Thermometer
from Oakton Instruments




Digi-Sense® Dual J-T-E-K Thermocouple Thermometer from Oakton Instruments

Back to Temperature Portable Meters and Thermometers

Digi-Sense® Dual J-T-E-K Thermocouple Thermometer

Use for single temperature readings or simultaneous dual temperature readings

 

 

 

Multi-data display shows both temperatures and the temperature differential simultaneously
Nonvolatile memory stores up to 25 sets of readings
Intrinsically safe UL listed: certified for Class I: Groups A, B, C, and D, Division 1
0.1°/1° selectable resolution
Takes differential temperature measurements
HOLD function freezes reading until you can log it
Meter accepts all type J, T, E and K thermocouple probes with miniconnectors

 

Choose the Digi-Sense dual J-T-E-K thermocouple thermometer for single temperature readings or simultaneous dual temperature readings. Meter accepts all type J, T, E, and K thermocouple probes with miniconnectors; select probe type with J-T-E-K key. Meter is °F/°C selectable and features ergonomic design, sealed silicone rubber keypad, IP54 splash- and dust-resistant case,

ABS/polycarbonate plastic case, and a built-in tilt stand.

Take differential temperature measurements with the T1/T2 function. The multi-data LCD simultaneously indicates the readings of each probe, as well as the differential reading. The meter resolution is keypad selectable for improved readability with rapidly changing temperatures. Above 999.9°, the thermometer automatically switches from 0.1° resolution to 1° resolution, below –150°C meters autorange to a 1°C resolution. Use the manual field calibration feature to do either a single- or a dual-point calibration for each probe to nearly any known temperature standard.

Each thermometer is individually factory calibrated on an NIST-traceable calibrator. The thermometer has ±0.05°F conformity to NIST calibration tables.

Type J-T-E-K
Range J: –328 to 1832°F (–200 to 1000°C)
K: –418 to 2501°F (–250 to 1372°C)
T: –418 to 752°F (–250 to 400°C)
E: –418 to 1832°F (–250 to 1000°C)
Resolution Below –150°: autoranging to 1°
From –150 to 999.9°: 0.1° Above 999.9°C: 1°C
Accuracy Below –150°C (–238°F): ±0.25% of rdg + 1°C (2°F)
Above–150°C(–238°F): ±0.1% of rdg + 0.4°C (0.7°F)
Input connector standard miniconnector
Display three 4-digit displays; 0.4"H and 0.2"H
Power two AA batteries (included); approximately 750 hours battery life
Probe thermocouple probe with miniconnector
Dimensions 3.3"W x 6.2"H x 1.2"D

Site Designed And Maintained By Panther Marketing And Design