Benchtop Conductivity Meter,CON 510,Oakton Instruments

Benchtop Conductivity Meter CON 510 from Oakton Instruments




Benchtop Conductivity Meter CON 510 from Oakton Instruments

Back to Conductivity Benchtop Meters

CON 510 Benchtop Conductivity Meter

An affordable way to take consistent, accurate conductivity measurements in your laboratory

 

 

 

 

Dual display shows both conductivity or TDS and temperature in °C or °F
Single- and multi-point automatic or manual calibration: customize meter calibration for quick checks or for best meter accuracy
Auto ranging across five ranges: offers the best resolution for your measurements
Advanced set up mode: recalls previous calibration data, conductivity/TDS effective cell constants per range, and more
Built-in non-volatile memory: stores up to 50 conductivity or TDS readings with corresponding temperature
Automatic or manual temperature compensation
Selectable cell constant
Adjustable conductivity to TDS conversion factor and temperature coefficient: gives highest accuracy in any solution
Selectable normalization temperature: choose between 15°C and 20°C
Built-in electrode holder arm; selectable "Ready" indicator; Hold function; diagnostic error messages
Includes WD-35608-50 conductivity cell
Measures Conductivity, TDS, °C, °F
ConductivityRange 0 to 19.99
0 to 199.9
0 to 1999 µS
0 to 19.99 mS
0 to 199.9 mS
ConductivityResolution 0.01 µS
0.1 µS
1 µS
0.01 mS
0.1 mS
ConductivityAccuracy ±1% full scale or ±1 digit
ConductivityCalibration Automatic: single or multi-point up to 4 points (84 µS,1413 µS, 12.88 mS, 111.8 mS)
Manual: single or multi-point up to 5 points (one user selectable point per range for multi-point calibration)
TDSRange 0.00 to 9.99 ppm
10.0 to 99.9 ppm
100 to 999 ppm
1.00 to 9.99 ppt
10.0 to 99.9 ppt
100 to 200 ppt
TDSResolution 0.01 ppm
0.1 ppm
1 ppm
0.01 ppt
0.1 ppt
TDSAccuracy ±1% full scale or ±1 digit
TDSCalibration Automatic: single or multi-point up to 4 points (84µS, 1413µS, 12.88mS, 111.8mS)
Manual: single or multi-point up to 5 points (one user selectable point per range for multi-point calibration)
TemperatureRange 0.0 to 100.0°C
32 to 212.0°F
TemperatureResolution 0.1°C or °F
TemperatureAccuracy ±0.5°C or ±0.9°F
TemperatureCalibration offset 0.1° increments up to ±5°
Memory up to 50 sets with temp
Cell constant selectable 0.1, 1.0, 10
Temperature coefficient adjustable from 0 to 10% per °C or °F
Dimensions 9"W x 2-3/8"H x 7"D
Shipping weight meter only 1.25 lbs. (0.6 kg); boxed 3 lbs (1.4 kg)