Model 597
A heavy-duty, corrosion-resistant automatic monitor/control for rinse water
The Myron L CONTROLSTIK Rinse Tank System dramatically reduces the amount of water used in continuous flow rinse tanks. At the same time, it automatically maintains optimum water purity, ensuring effective rinsing.
Since water flows only when parts are rinsed, you save money on water bills, sewer use charges, and waste water treatment expenses.
Features
- Cuts water consumption up to 85%
- Reliable solid-state electronics
- Corrosion-resistant design
- Minimal maintenance
- Panel or surface mount design
- Attractive panel design allows for
either surface or panel mounting
|
How it works
The three parts of the CONTROLSTIK System are easily installed. The CONTROLSTIK (conductivity sensor) is set at a tolerable contamination level and submerged in the tank. Fresh water cannot flow into the tank until drag-in from rinsed parts causes the contamination level in the tank to rise above the pre-set point. The CONTROLSTIK (sensor) then signals the solenoid valve to open, adding fresh water. As soon as this fresh water dilutes the contamination to the tolerable pre-set level, the CONTROLSTIK (sensor) closes the valve.
Engineering Specifications
Rinse water usage shall be minimized by means of automatic conductivity control systems. They shall consist of a temperature compensated conductivity sensor, corrosion resistant one-inch solenoid valve and transformer box which safely reduces line power to the probe and sensor. Circuitry shall be solid-state and unaffected by changes in voltage between 105 and 125 volts. Setpoint adjustment shall be on sensor to minimize tampering. Rinse tank controls shall be Myron L Model 597 or approved equal.
Transformer Box Specifications |
| Input Power |
Choice of 115 or 230 VAC, 50/60 Hz, Automatic voltage regulation ensures operation of the systems from 105-125 VAC or 210-250 VAC respectively |
| Output |
24 VAC @ 600 milliamps AC |
| Maximum power consumption |
12 watts (103 milliamps) @ 117 VAC |
| Lights |
LEDs indicate POWER (red) and VALVE (yellow) |
| Line cord |
8' (2.4 m), 18 ga., 3 conductor plug (with 115 VAC system only) |
| Installation |
Mounts easily in panel; or on wall (surface mounting plate provided)
Terminal strip for fast wiring |
| Enclosure |
Model 595 Controlstik only - ABS corrosion resistant plastic
Model 597 Controlstik II only - NEMA 12 fiberglass case with heavy gasket and 316 stainless steel hardware |
| 597 Electrical Installation |
Either HARDWIRE with 5/8" conduit, or PLUG-IN with 8' (2.4 m), 18 ga.,
3-conductor plug (supplied with 120 VAC systems only) |
CONTROLSTIK Sensor Specifications |
| Ranges |
5-500 micromhos (for high quality water);
500-5000 micromhos (for normal tap water) |
| Power |
1 VAC (from transformer box) |
| On-Off Span |
Approximately 5% of setpoint |
| Temperature Compensation |
Automatic to 180°F (82°C) |
| Cord |
10' (3 m) 22 ga., 4 conductor, vinyl jacketed (longer cords available) |
| Installation |
ABS bracket supplied |
| Materials |
Epoxy and 316 stainless steel |
| Dimensions |
12" (304 mm) Long, 1" (25 mm) Diameter |
Solenoid Valve Specifications |
| Size |
1" NPT normally closed - compatible with plastic or metal piping |
| Power |
24 VAC (from transformer box) |
| Materials |
Body - glass reinforced nylon;
Diaphragm - nylon reinforced BUNA N synthetic rubber;
All exposed metal - stainless steel |
| Operating Pressure |
10-100 psi (69-690 kPa) |
| Miscellaneous |
Adjustable flow control; manual override; anti-hammer closing, conduit connector |
|