Process Controls Home
|
|
|
| |
|
Products
|
|
|
|
|
| |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| pH/ORP/Conductivity Controllers and Monitors from Myron L Company |
- AQUASWITCH - Fully Automatic DI Bank Switching System
The AQUASWITCH is a special purpose dedicated computer which automatically "changes out" an exhausted DI bank for a fresh, stand-by bank. LEDs continually give the condition of both banks. An alarm output is activated as each bank is depleted.
- CONTROLSTIK - Rinse Tank System
The Myron L CONTROLSTIK Rinse Tank System dramatically reduces the amount of water used in continuous flow rinse tanks. At the same time, it automatically maintains optimum water purity, ensuring effective rinsing.
- 750 Series II - Conductivity/TDS Monitors/Controllers
The unique circuitry of the 750 Series II Conductivity Monitor/controllers guarantee accurate and reliable measurements. Drift free performance is assured by "field proven" electronics, including automatic DC offset compensation and highly accurate drive voltage.
- CTCII Conductivity/TDS - Chemical Treatment Controller / Cooling Tower Controller
The unique circuitry of the CTCII Chemical Treatment Controller guarantees accurate and reliable measurements. Drift free performance is assured by field proven electronics, including automatic DC offset compensation and highly accurate drive voltage. Since temperature compensation is at the heart of accurate water measurement, all Myron L CTCII controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models corrected to 25°C.
- 750 Series II - Resistivity Monitors/Controllers
The unique circuitry of our 750 Series II Resistivity Monitor/controllers guarantee accurate and reliable measurements. Drift free performance is assured by "field proven" electronics, including automatic DC offset compensation and highly accurate drive voltage.
- 720 Series II - pH/ORP Monitors/Controllers
The advanced "isolated" circuitry of the 720 Series II pH/ORP Monitor/controllers guarantees accurate and reliable measurements completely eliminating ground-loop and noise issues.
- RO-CHECK POU TDS MONITOR
The innovative Myron L RO-CHECK (U.S. Patent # 4,762,611) reliably monitors total dissolved solids 24 hours a day. A quick glance at the display assures RO users of their water TDS quality. Should membrane failure or other problems cause TDS to rise above the set point, the words "CHECK SYSTEM" flash in the LCD. This silent indicator alerts, rather than alarms, the user that service may be required.
|
|
|