Temperature Transmitters - DIN Mount, Head Mounted
|
|
V 608 Temperature Transmitter
|
|
Input:
| Thermocouple, RTD
|
Output:
| 4-20 mA
|
|
- PC Programmable
- Programmable Sensor Fault Response
- Non-Isolated
- 12-30 VDC Loop-Powered
|
 Specifications Instructions
|
|
V 611
Ultra-Slim Temperature Transmitter
|
|
Input:
| Thermocouple, RTD
|
Output:
| 4-20 mA
|
|
- 9 mm (0.35") wide
- PC Programmable
- Reverse Output Capable (20-4 mA)
- 100 Ohm RTD, 2, 3, or 4-wire
- T/C J, K, T, E, R, S,N, B, L, U, W5, W3
- Input Linearization
- Non-Isolated
- Internal or External CJC
- Supply Voltage:12-30 VDC from Output Loop
|
 Specifications Instructions
|
|
|
V 624 Programmable Temperature Transmitter
|
|
Input:
| Thermocouple, RTD,
Thermistor, Custom
|
Output:
| 0-2 mA to 0-20 mA, 20-0 mA
0-1 V to 0-10 V, 10-0 V
|
|
- PC Programmable
- Reverse Output Programmable
- Custom Input Linearization
- Programmable Sensor Fault Response
- Removeable Plugs
- 3.7 kV Input/Output/Power Isolation
- Supply Voltage: 24-60 or 85-230 VAC/VDC
|
 Specifications Instructions
|
|
V 604s Programmable Universal Transmitter
|
|
Two
Inputs:
| ±1000 mVDC to ±300 VDC
±50 mADC
Thermocouple, RTD,
Thermistor or Potentiometer 0-5k Ω
|
Two Outputs:
(common ground)
| 0-5 mA to ±40 mA
0-4 V to -12-15 V
One relay
Modbus communications
| 
|
- PC Programmable
- Unipolar or Bipolar Input and Output
- Reverse Output Programmable
- Custom Input Linearization
- Programmable Alarm Relay
- 3.7 kV Input/Output/Power Isolation
- Supply Voltage: 24-60 or 85-230 VAC/VDC
|
 Specifications Instructions
|
|
V 604 Programmable Universal Transmitter
|
|
Input:
| 0-2 mV to ±40 V
0-80 µA to -50-100 mA
Thermocouple, RTD, Thermistor, Potentiometer
|
Output:
| 0-5 mA to ±40 mA
0-4 V to -12-15 V
| 
|
- PC Programmable
- Unipolar or Bipolar Input and Output
- Reverse Output Programmable
- Custom Input Linearization
- Programmable Alarm Relay
- 3.7 kV Input/Output/Power Isolation
- Supply Voltage: 24-60 or 85-230 VAC/VDC
|
 Specifications Instructions
|
|
VC 603 Programmable Universal Transmitter with Alarms
|
|
Input:
| 0-2 mV to ±40 V
0-80 µA to -50-100 mA
Thermocouple, RTD, Thermistor, Potentiometer
|
Output:
| 0-5 mA to ±40 mA
0-4 V to
-12-15 V 1 DPDT, 2 SPDT
|
|
- PC Programmable
- 3 Independently Configurable Alarm Contacts
- Unipolar or Bipolar Input and Output
- Reverse Output Programmable
- Custom Input Linearization
- 3.7 kV Input/Output/Power Isolation
- Supply Voltage: 24-60 or 85-230 VAC/VDC
|
 Specifications Instructions
|
|
|
|
VK 616 Temperature Transmitter
|
|
Input:
| Thermocouple, RTD
|
Output:
| 4-20 mA
|
|
- PC Programmable
- Programmable Sensor Fault Response
- Isolated and Non-Isolated Versions
- 12-30 VDC Loop-Powered
|
 Specifications Instructions
|
|
|
VK 636 Profibus Temperature Transmitter
|
|
Input:
| Thermocouple, RTD
|
Output:
| Profibus PA
|
|
- PC Programmable

- Profibus Process Automation Protocol
- Programmable Sensor Fault Response
- Isolated
|

|
|
B 840 Multi-Channel Loop Power Supply
|
|
Input:
| 24, 115, or 230 VAC |
Output:
| 4-20 mA, 24 VDC |
|
- 4-Channel 4-20 mA, 24V DC Versions
- LED Monitor for Each Channel
- Each Channel Isolated
- Supply Voltage: 24, 115, or 230 VAC 50/60 Hz
- 30 mA Current Limiter for Each Channel
|
 Specifications Instructions
|
|
B 812 Loop Power Supply with Signal Output and HART Communications
|
|
Input:
| 4-20 mA, 18 to 25.5 VDC
Source resistance 330 Ω |
Output:
| 4-20 mA, 17 VDC no load
Permitted load: 750 Ω, 550 Ω with HART |
|
- 3.6 kV Input, Output, and Power Isolation
- Red LED for Open and Short Circuit Fault Detection
- Designed for HART Protocol
- Supply Voltage: 20-70 or 60-265 VAC/VDC (45-400 Hz for AC)
|
 Specifications Instructions
Brochure
|
|