ACR SmartReader data loggers are multi-channel, user configurable data loggers that are able to monitor a variety of parameters. Durability is assured with a 3-year logger warranty and 10-year battery life.
Common Specifications
|
Size
|
107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9") |
|
Weight
|
110 g (3.75 oz) |
|
Case Material
|
Noryl® plastic |
|
Operating Limits
|
-40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing) |
|
Clock Accuracy
|
+/- 2 seconds per day |
|
Battery
|
3.6 volt Lithium, 1 Amp-Hour |
|
Power Consumption
|
5 to 10 microamps (continuous) |
|
Battery Life
|
10 years under normal use (factory replaceable) |
|
Mounting
|
Magnetic backing or locking eyelet |
|
Memory Size
|
32 K (32,768 readings) |
|
Sampling Method
|
1. Continuous (First-in, First-out)
2. Stop when full (Fill-then-stop) |
|
Sampling Rate
|
User selectable rates between 8 seconds to once every 5 days |
|
Resolution
|
8-bit (1 part in 256) |
|
External Connector
|
Removable screw-type terminal strip with Common (-) connection |
|
PC Requirements
|
IBM PC or 100% compatible with at least 2MB RAM, 2MB of hard drive disk space and one free serial port |
|
Software Requirements
|
TrendReader® 2 (compatible with Windows® 2000, XP and Vista 32bit) |
|
Internal Temperature Sensor Type
|
NTC thermistor (10,000 ohms @ 25°C [77°F]) |
|
Internal Temperature Sensor Range
|
-40 to 70°C (-40 to 158°F) |
|
Internal Temperature Sensor Accuracy
|
+/- 0.2ºC over the range: 0 to 70ºC (+/- 0.3ºF over the range: 32 to 158ºF) |
|
Internal Temperature Sensor Resolution
|
0.4ºC (0.7ºF) @ 25ºC;
better than 1ºC (1.8ºF) between -25 and 70°C (-13º and 158ºF);
better than 2.0ºC (3.6°F) between -40 and -25°C (-40ºF and -13ºF) |