The FuzyPro 8010 is a 1/8 DIN microprocessor based digital indicator. Available with red or green displays. One latchable relay is fitted as standard, plug-in modules allow two more alarm relays, PV retransmission or transmitter PSU.
-
- Up to 3 alarms
- transmitter PSU option
- Min/max value hold
- Engineering units
- PC configuration
- PV retransmit option
- RS485 comms option
Features:
| Output Configuration |
Up to 3 total, max 3 for Alarms, max 1 for retransmit of PV, max 1 transmitter power supply |
| Alarm 1, 2 & 3 Types |
Process high, process low, direct acting, process high, process low reverse and logical OR |
| Viewable Values |
Process variable, maximum value, minimum value and elapsed time since reset |
| Legends |
ºC/ºF LED, Labels for 27 other common units, mounted behind clear window |
| Human Interface |
3 button operation, 4 digit 13 mm high red or green display, plus setup, alarm,
max & min indicators |
| PC Configuration |
Off-line configuration from serial port to dedicated config socket
(comms option not required) |
Input:
| Thermocouple |
J, K, R, S, T, B, L, & N |
| RTD |
3 wire PT100 50 per lead maximum (balanced) |
| DC Linear |
0-20/4-20mA, 0-50/10-50mV, 0-5/1-5/0-10/2-10V. Scalable -1999 to 9999, dec point available |
| Impedance |
>100M for Thermocouple and mV ranges, 47K for V ranges and 4.7 for mA ranges |
| Accuracy |
+/- 0.25% of input scan +/- 1 LSD (T/C CJC better than 0.7ºC) |
| Sampling |
4 per second, 14 bit resolution approximately |
| Sensor Break Detection |
<2 secs (except zero based DC ranges),
*high alarms activate (*low for RTD, mA or V) |
Outputs & Options:
| Alarm 1 Relay |
Contact SPDT 2Amp resistive at 240V AC, >500,000 operations, latching or non-latching. Fitted as standard |
| Alarm 2 & 3 Relays |
Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations (optional) |
| Retransmit Output |
0-20/4-20mA to 500 max, 0-10/0-5V into 500 min.
Accuracy typically +/- 0.25% |
| Transmitter Power Supply |
20-28V DC (24V nominal), max load 910 (22mA at 20V) |
| Remote Reset |
External reset of latching alarm 1 relay. Volt free or TTL input (Reset = open to close or "0" to "1" transition. 0 = -0.6 to 0.8V, 1 = 2 to 24V) |
| Communications |
2 wire RS485, 1200 to 9600 baud. Modbus or West ASCII (selectable) |
Operating & Environmental:
| Temperature & RH |
0 to 55ºC (-20 to 80ºC storage), 20% to 95% RH non-condensing |
| Power Supply |
100 to 240V 50/60Hz (optional 20 to 55V AC/22 to 65V DC), approx 4 Watts |
| Front Panel Protection |
IEC IP66 (Behind panel protection is IP20) |
| Approvals and Certification |
CE, UL & ULc |
|