Permanently record pressure, flow, level, temperature, or other process variables with the Model CR20 Universal Input Recorder: The microprocessor-based unit accepts input from two-wire transmitters or sensors with a 1 - 20 mA, 4 - 20 mA, 0 - 5 VDC, or 1 - 5 VDC output. Monitor and record remote process signals on the 8" (20 cm) diameter chart paper: Units feature user selectable output ranges and recording times, and high/low alarms.View current measurements on the large LCD or recall minimum and maximum values.
Model CR20 Circular Chart Recorder includes CR776 chart paper (0 to 100 range, 7 day, 100 sheets), one pen, AC adapter, and instruction manual.
PHYSICAL DATA
Accuracy: ± 0.3% of full scale, ± 1 digit.
Input Ranges: 0 to 20 mA, 4 to 20 mA, 0 to 5 VDC, 1 to 5 VDC (selectable).
Input Connection: Two screw terminals.
Maximum Input Voltage: 5 volts (unit records direct currect-dc).
Output Ranges: 0 to 100.0, 0 to 140.0, 0 to 150.0, 0 to 200.0, 0 to 250.0, 0 to 300.0, 0 to 450.0, 0 to 500.0, 0 to 600.0, 40.0 to 110.0, -10.0 to 10.0, -15.0 to 25.0, -20.0 to 50.0, -20.0 to 120.0, -30.0 to 50.0, -50.0 to 50.0 (selectable, including decimal point selectability).
Recording Times: 1, 7, 14, 31 day (selectable).
Average Response Time: 20 seconds full scale.
Chart Size: 8" (20.3 cm) diameter.
Display Resolution: .001, .01, .1, or 1 depending on range selected.
Calibration: User calibration of zero.
Alarms: Audio/visual high and low, and over current.
Ambient Operating Temperature: 32 to 122°F (0 to 50°C), 0 to 90% RH (non-condensing).
Power Supply: 120 VAC adapter (included) or four "D" batteries (response time is slower when using battery power source, batteries are suggested for back-up power).
Mounting: Free standing or wall mountable.
Dimensions: 10 ½" H x 13 7/8" W x 2 ½" D (26.7 x 35.2 x 6.4 cm).
Weight: 7 lbs (3.2 kg).