EBT721 Balometer Capture Hood, Alnor

EBT721 Balometer® Capture Hood from Alnor

 EBT721 Balometer® Capture Hood
EBT721 Balometer Capture Hood

The EBT721 Balometer Electronic Balancing Tool features a detachable multi-purpose digital manometer that can be used with a variety of common test and balance tools, such as pitot, air foil, temperature, relative humidity probes or a 16-point velocity matrix. It will become the tool of choice for contractors and facilities personnel because of its ergonomic design and extremely light weight.

Models
EBT721 Models
model number description
EBT721-A1 2' x 2' air capture hood/frame/base, Manometer, 4 AA size rechargeable NiMH batteries, external battery charger, AC Adaptor, 18" Pitot probe, 2 Static Pressure probes, 16 ft. Neoprene tubing, Wheeled luggage style carrying case, NIST-traceable calibration certificate, CompuDAT™ PC downloading software, and manual.
EBT721-X1 -A1plus 16-point Velocity Matrix with telescoping handle
EBT721-O1 -X1 plus Temperature Probe
EBT721-Z1 -O1 plus Relative Humidity/Temperature probe, Air Flow Probe

Note:
For EBT720 or 721 with European AC adapter, change to –A2, -X2, -02, -Z2
For EBT720 or 721 with UK AC adapter, change to –A3, -X3, -03, -Z3
For EBT720 or 721 with Australian AC adapter, change to –A4, -X4, -04, -Z4


EBT720/EBT721 Specifications
EBT720/EBT721 Specifications
range differential pressure ±15 in. H2O, (3735 Pa) 150 in. H2O maximum safe operating pressure
absolute pressure 15 to 40 in. Hg (356 to 1016 Hg)
velocity 25 to 8,000 ft/min (0.125 to 40 m/s) pitot probes;
25 to 5,000 ft/min (0.125 to 25 m/s) air flow probe;
25 to 2,500 ft/min (0.125 to 12.5 m/s) velocity matrix;
volume 25 to 2,500 ft3/m (42 to 4250 m3/h) capture hood
RH 0 to 95% RH (optional probe)
temperature -40 to 250 degrees F (-40 to 121 degrees C) probe dependant
resolution pressure 0.00001 in. H2O (0.001 Pa) Static & Differential Pressure
0.001 in. Hg (1 mm Hg) Absolute Pressure
velocity 0.1 ft/min (0.1 m/s)
volume 0.1 ft3/min (0.1 m3/h)
RH 0.1% RH
temperature 0.1 degrees F (0.1 degrees C)
accuracy pressure ±2% of reading ±0.001 in. H2O, (0.025 mm H2O; ±2% of reading ±0.001 in. Hg) Absolute
velocity ±3% of reading ±7 ft/min (0.04 m/s) 25 to 8,000 ft/min (all velocity probes) > 50 ft/min
volume ±3% of reading ±7 ft3 /min 25 to 2,500 ft3/min > 50 ft/min
RH ±3% RH
temperature ±0.5 degrees F (0.3 degrees C) from 32 to 160 degrees F (0 to 71 degrees C) typically ±1.0 degrees F (0.6 degrees C) from -40 to 32 degrees F (-40 to 0 degrees C) and from 160 to 250 degrees F (71 to 121 degrees C)
units pressure in. H2O, Pa, mm Hg, in. Hg
velocity ft/min, m/s, m/h
volume ft3/min, m3/h, m3/m, l/s
temperature degrees F, degrees C



Balometer Jr® Capture Hood from Alnor
Site Designed By Panther Marketing & Design