Process Control Home
|
|
|
| |
|
Alpha Controls
|
|
|
|
|
| |
|
|
|
|
|
 |
|
Intrinsic Safety Barrier Series 9000 INTRINSPAK
|
 |
INTRINSPAK®

Exploded view of a Type 9001 single channel barrier showing 35mm DIN rail, barrier, replacement fuse, and label holder. |
The world's first Intrinsic Safety Barrier with a replaceable fuse and direct DIN rail mounting and grounding all in a slim 1/2" wide housing. Introduced in 1992 and still the LOWEST RESISTANCE barrier available today! Choose from the Type 9001 single channel, Type 9002 dual channel, or Type 9004 single channel with electronic current limitation.
One Step, Snap-On 35mm DIN Rail Mounting and Grounding
... eliminates external ground bars, wiring, tools, and adapters.
Patented Replaceable 160mA Fuse
... provides overvoltage and reverse polarity protection.
Lowest Internal Resistance
... reduces circuit loading problems.
Slim 1/2" Wide Housing for Single and Dual Channel Versions
... conserves valuable rail space.
Short-Circuit Proof Connections
... prevents blown fuses when field wiring is shorted.
Approvals to Worldwide Standards
... FM, UL, CSA, PTB (CENELEC), MSHA, SA-
One step, snap-on 35mm DIN rail mounting and grounding
General Description
First introduced in 1991, the Series 9000 INTRINSPAK has quickly become the industry standard for intrinsic safety barrier design. Within the series the user can choose from the Type 9001 single channel, Type 9002 dual channel, or for applications requiring up to 3/4W of power, the Type 9004 single channel with electronic current limitation.
All three types share a common 1/2" wide housing which snaps directly to a 35mm DIN rail. Once mounted, an electrical connection is formed between the barrier and the rail. This rail now serves as the intrinsic safety ground bus when connected to the designated grounding point. Two additional ground lugs are provided and may be used as a redundant grounding method or for terminating shields.
Each barrier also contains a replaceable 160mA fuse cartridge for each channel. This fuse is located within the front faceplate and protects the barrier from pole reversal and voltage spikes at the input side (terminals 1 and 2). Unlike other safety barrier designs, this fuse will not blow should the field wiring be shorted to ground.
Safety barriers are polarity sensitive devices. Therefore they are available in +DC, -DC, and AC voltage ratings. They also contain an internal resistance which may cause loading problems in some applications. STAHL safety barriers have been designed to minimize this resistance and offer the lowest available ratings in the industry.
|
Powerful Solutions for Instrumentation & Control Problems!