Glass Thermometers

|
Complete Sets of ASTM Precision Factory-Calibrated
(Certified) Thermometers
|
|
Cat. No
|
No. of
Thermometers
|
ASTM Nos.
|
Ranges
Covered
|
|
62-70C-FC
|
9
|
62C70C
|
38 to 405°C
|
|
62-70F-FC
|
9
|
62F70F
|
36 to 761°F
|
|
Replacement Thermometers Purchased Separately
|
|
Cat No.
|
ASTM No.
|
Range
|
Div.
|
Length
|
Calibrated (Certified) at
|
|
62C-FC
|
62C
|
38 to 2°C
|
0.1°
|
379 mm
|
37°, 30°, 20°, 10°, 0°C
|
|
63C-FC
|
63C
|
8 to 32°C
|
0.1°
|
379 mm
|
7°, 0°, 10°, 20°, 30°C
|
|
64C-FC
|
64C
|
25 to 55°C
|
0.1°
|
379 mm
|
0°, 25°, 35°, 45°, 55°C
|
|
65C-FC
|
65C
|
50 to 80°C
|
0.1°
|
379 mm
|
0°, 50°, 60°, 70°, 80°C
|
|
66C-FC
|
66C
|
75 to 105°C
|
0.1°
|
379 mm
|
0°, 75°, 85°, 95°, 105°C
|
|
67C-FC
|
67C
|
95 to 155°C
|
0.2°
|
379 mm
|
0°, 100°, 110°, 130°, 150°C
|
|
68C-FC
|
68C
|
145 to 205°C
|
0.2°
|
379 mm
|
0°, 150°, 170°, 190°, 205°C
|
|
69C-FC
|
69C
|
195 to 305°C
|
0.5°
|
379 mm
|
0°, 200°, 235°, 270°, 305°C
|
|
70C-FC
|
70C
|
295 to 405°C
|
0.5°
|
379 mm
|
0°, 300°, 335°, 370°, 400°C
|
|
62F-FC
|
62F
|
36 to 35°F
|
0.2°
|
379 mm
|
35°, 15°, 0°, 15°, 32°F
|
|
63F-FC
|
63F
|
18 to 89°F
|
0.2°
|
379 mm
|
20°, 32°, 50°, 70°, 88°F
|
|
64F-FC
|
64F
|
77 to 131°F
|
0.2°
|
379 mm
|
32°, 80°, 95°, 115°, 130°F
|
|
65F-FC
|
65F
|
122 to 176°F
|
0.2°
|
379 mm
|
32°, 125°, 145°, 160°, 175°F
|
|
66F-FC
|
66F
|
167 to 221°F
|
0.2°
|
379 mm
|
32°, 168°, 185°, 200°, 220°F
|
|
67F-FC
|
67F
|
203 to 311°F
|
0.5°
|
379 mm
|
32°, 205°, 240°, 275°, 310°F
|
|
68F-FC
|
68F
|
293 to 401°F
|
0.5°
|
379 mm
|
32°, 300°, 340°, 370°, 400°F
|
|
69F-FC
|
69F
|
383 to 581°F
|
1.0°
|
379 mm
|
32°, 400°, 460°, 520°, 580°F
|
|
70F-FC
|
70F
|
563 to 761°F
|
1.0°
|
379 mm
|
32°, 570°, 640°, 700°, 760°F
|
Need LIG thermometers? These Ertco models are manufactured in strict accordance with ASTM precision specifications and provide accurate and reproducible measurements. These total-immersion thermometers are perfect for critical temperature measurements or as calibration standards.
When used properly, these thermometers typically have errors of less than ±.01% of scale. Each one is accurate to ±1 scale division, and stem diameters vary from 7 to 8 mm. Individual serial numbers are given to each unit.
Every LIG thermometer is factory calibrated against NIST standards. The NIST-traceable certificate gives the ice point reading, five calibration points, tabulated corrections (to one-tenth of the smallest scale division) for each calibration point, the serial and test number of the NIST standard and test notes.
|